Electrical Accessories information Electrical Accessories
Streamline Trunking information Streamline Trunking
Healthcare Solutions information Healthcare Solutions
Tele-Call information Tele-Call
Telepoint information Telepoint
Disability Systems information Disability Systems
Security Products information Security Products
Hygiene Products information Hygiene Products
Home
home > electrical accessories > special applications

  Special application accessories
   
  Mercury Switches
  Mercury switches are for use in hospital operating theatres, laboratories, etc. where certain explosive gases and vapours are present. They are constructed so that electrical contact is made and broken by means of mercury in a sealed tube which eliminates open sparking.
 
    15amp Single Pole Twin 15amp Single Pole
    700/SS 701/SS
Plate/Interior Assembly   700/SS 701/SS
Quick Links       
Boxes:      
Flush (metal)   1751 1753
Surface (metal)   1752 1754
   
  Mercury Switches with Protective Hinged Cover Plates
  Protected mercury switches use the same interiors as described above and are used where protection is required. Cover plates are in stainless steel (SS) with satin rocker.

Switch rating: 15amp 250V AC.
 
    15amp Single Pole Twin 15amp Single Pole
    710/SS 711/SS
Plate/Interior Assembly & Hinged Lid

  710/SS 711/SS
Quick Links       
Boxes:      
Flush (metal)   1751 1753
Surface (metal)   1752 1754
   
  Mercury Switched Sockets

Interlocking plug

Interlocking plugs

 

Spare plug ref: 43

Mercury switch sockets are designed with an interlock so that the plug cannot be removed when the switch is in the ‘ON’ position.
    13amp Single Pole Twin 13amp Single Pole
    702/SS 703/SS
Plate/Interior Assembly

  702/SS 703/SS
Quick Links       
Boxes:      
Flush (metal)   1755 1757
Surface (metal)   1756 1758
   
  Mercury Switched Sockets with Protective Hinged Cover Plates
  Protected mercury switch sockets use the same interiors as described above and are used where protection is required. Cover plates are in stainless steel with satin rockers. All mercury and protected mercury switch sockets include interlocking plugs.
 
    13amp Single Pole Twin 13amp Single Pole
    712/SS 713/SS
Plate/Interior Assembly
  712/SS

713/SS

Quick Links       
Boxes:      
Flush (metal)   1755 1757
Surface (metal)   1756 1756
Centres of conduit entries must be within 20mm of the back of the box to ensure cables do not interfere with the free operation of the mercury switch.
   
  One Gang Switch with Protective Hinged Lid
 
      Twin 13amp Single Pole
      750/SS
Protective Plate Assembly

    750/SS
Quick Links       
Boxes:      
Flush (metal)     1842
Surface (metal)     1743
   
  Switch Interiors (Protected Range Only)
  The Protected range is for use in hospital operating theatres, laboratories etc., where protection is required. Cover plates are stainless steel (SS) with satin chrome rocker, white trim and socket interiors.
 
  Switch Switch Switch
Unit

Switch Switch Switch
Type 2 way Double pole Intermediate
Reference 131/SC 132/SC 133/SC
 
Various switch interiors can be fitted, as follows:
Switch Interior 2 way double pole intermediate
20amp 131/SC 132/SC 133/SC
   
  Switched Sockets with Protective Hinged Lid
 
    13amp Single Pole 13amp Twin
    751/SS 752/SS
Protective Plate/Interior Assembly

  751/SS 752/SS
       
Boxes:      
Flush (metal)   1843 1844
Surface (metal)   1746 1747
   
  Wemlock Switches, Sockets & Lockable Enclosure
   
  Switches
  Wemlock units are key operated and withdrawal of the key ensures there is no unauthorised use. Cover plates are of stainless steel.
 
    390 392
Plate Assembly

  390 392
       
Boxes:      
Flush (metal)   1702 1703
Surface (metal)   1131 1134
Surface (plastic)   1132 1133
 
Various switch interiors can be fitted into the Wemlock switch range as follows:
Switch Interior 1 way 2 way double pole intermediate
20amp 10/B 11/B 12/B 13/B
Pair of spare keys available, reference 399.
   
  Switched Socket
  The Wemlock 13amp switched socket works in the same way as Wemlock switches ensuring that power cannot be provided without key operation.
Plugs ref: 40.
 
      395
Plate Assembly

    395
       
Boxes:      
Flush (metal)     1703
Surface (metal)     1134
Surface (plastic)     1133
   
  Lockable Enclosure
  A lockable enclosure suitable for use in shopping precincts or other areas where restricted use is required. The hinged lid is finished in stainless steel. Each unit is supplied with two internal plates to accept 1 or 2 gang accessories from our series 2 range. Accessories must be ordered separately with their respective front plates and grids.

Top cover overall: 186 wide x 150 high.
Box 166 wide x 130 high x 50 deep.
Flush, wall fitting only.
 
      Lockable Unit
Lockable Unit (supplied without Socket outlet)

    396
Spare key set     399
   
   
  Mains Voltage Indicators
  The 240 volt indicators are suitable for use as warning lights for dark rooms, dispensary alarms, remote lights connected to security cupboards for controlled drugs and ‘room engaged’ signs.

Cover plate finishes are stainless steel (SS).

Red lenses are supplied as standard. Alternative replacement lenses, reference QD337, are available in green (GR), blue (BL), amber (A), clear (CL).
 
    371 372
Plate Assembly (Red lens)

  371 372
       
Boxes:      
Flush (metal)   1732 1733
Surface (metal)   8384 8385
   
  Isolators
  Isolators are used in commercial or industrial applications such as kitchens, laundries, laboratories, etc., where plant requires isolation for maintenance or in emergencies.

Cover plates are stainless steel (SS).

Switching is rated 100A 500V, 50/60 Hz to BS EN 60947-3.
 
  362 363 364
Plate Assembly

362 363 364
       
Boxes:      
Flush (metal) 1736 1736 1736
Surface (metal) 1737 1737 1737